Hi Gents!
I'm in big trouble. :(
Attachment 219089
I made the following process:
normalizing: none.
soaking: ~805C/1480F, 15 min.
quenching oil: 50C, 30-40 sec.
tempering: after cool enough to touch, 205C/400F, 2x1h (between cooling to room temperature)
It seemed all right but I can't sharpen the blade. The edge is very sensitive (see the pic). What did I do wrong?
More picture from the heat treatment process (on the first pic: the first few minutes on 1480F):
Attachment 219094Attachment 219095Attachment 219096Attachment 219097Attachment 219098Attachment 219099